Selected Scanner & Cable Part Numbers for LANpoint Terminals

Here is information you can use when purchasing some scanners from third parties. These are by no means the only scanners that will work with Intelligent Instrumentation terminals, since they are open-architectured, but this is a sampling.

The decoded scanners that have PS/2 cables can be attached to the external keyboard port on LANpoint terminals.

The decoded scanners that have RS232 cables can be attached to a COM port on LANpoint terminals.

The decoded scanners that have wand emulation output and can be attached to the to the LANpoint PRO, FACTORYpoint PRO, and LANpoint CE "barcode" port.

The undecoded scanners that have laser output can be attached to the LANpoint PRO, FACTORYpoint PRO, and LANpoint CE "laser" port.

We supply some of the scanners listed below. If you purchase the scanner from us, the correct cable is included and any configuration variables are set to work correctly or have explicit instructions included for doing so.


Some Selected Scanners for use with LANpoint Terminal Families

Manufacturer

Manufacturer Part Number

Manufacturer Cable Number

 

Decoded barcode output scanners for the "barcode" port on LANpoint PRO, FACTORYpoint PRO, LANpoint CE, and all TM data collection terminals

 

Symbol

LS2208

CBA-W01-S07ZAR

Symbol

LS-1004-I100-7700Z ***obsolete by Symbol***

STI-10-0252

Symbol

LS-3603-I200A(or I200E) ***obsolete by Symbol - see Symbol P302FZY***

25-08914-01

Symbol

LS-4004-I000-7700Z

STI-10-0252

Symbol

LT-1810-I100A(or I100E)

25-10735-01

Symbol

P302FZY-I000

25-39803-01

PSC

Powerscan 0611001-010004-100

PSC8-0422-02REVA2600

Symbol

LS1902T-I000

25-51618-21

Hand Held Products (HHP)

3800LR-12

42204983-08

Hand Held Products (HHP)

IT3800LX4LR-12

42203764-03

 

Undecoded (laser) output scanners for the "laser" port on LANpoint PRO, FACTORYpoint PRO, LANpoint CE

 

PSC

Powerscan PSXLR-0000 and PSXLR-0110 (Long Range)

8-0419-01 REV A

Symbol

LS-1000-I000-01 ***obsolete by Symbol - see Symbol LS1900T and cable 25-32464-20***

Includes cable

Symbol

LS1900T-I000

25-32464-20 REV A

Symbol

LS-3200-I300A(or I300E) ***obsolete by Symbol - see Symbol P300STD***

25-06711-01

Symbol

LS-4000-I000-01

Includes cable

Symbol

LT-1800-I100A(or I100E)

25-05611-03

Symbol

P300STD

25-38697-01 REV A 0022 26576A UNDECODED

PSC

Powerscan 0613001-010000-500

PSC8-0419-01REVAPIE

 

Serial RS-232C scanners for a COM port

 

Symbol

LS2208

CBA-R01-S07PAR

PSC

Powerscan PSLR-1000 (Long Range), or
PSXLR-1000(Extra Long Range)

PSC 8-0423-03 REV B PIE

Hand Held Products (HHP)

3800PDF-12

42206132-02 (IBM PS-2 3800)

Hand Held Products (HHP)

IT3800LR-12...The scanner defaults to 9600 baud, even parity, 7 bits, and 1 stop bit, whereas our 'wedgece' program defaults to 9600 baud. no parity, 8 bits, and 1 stop bit. So, they need to be made to match.

42205895-01

Symbol LS1902T-I000

25-32465-20

 

Hand Held Products (HHP)

ST5750ALR

42205954-04

 

Keyboard wedge IBM PS/2 output scanners for an external keyboard port

 

Symbol

LS2208

25-62417-20

PSC

Powerscan PSLR-1000(Long Range), or
PSXLR-1000 (Extra Long Range)

PSC 8-0424-03-B

Hand Held Products (HHP)

3800PDF-MDKIT

Includes cable

Symbol

Hotshot LS2106-I000

25-31828-01

 

Scanners for USB ports on LANpoint XL

 

Symbol

LS3408-FZ200005

CBA-U01-S07ZA

Datalogic

Heron-G D130, CCD-Gun, PN:902401000

USB cable, CAB-412, PN:90A051902

Datalogic

Firescan D131, Laser-Gun, PN:902351122

USB cable, CAB-412, PN:90A051902


Some scanners need minor setup on the scanner (scanning certain barcodes in the scanner's setup manual). Here are some specifics:

Scanner

Configuration Instructions

Symbol LS2208

When using this scanner, you may want to program the suffix to be <CR> or <CR/LF> by scanning the "Miscellaneous Settings barcodes on the LS2208 Quick Start Guide; Note that if you pick the serial-connect version of this scanner/cable, that you will need to configure it as "STANDARD RS-232". The default serial configuration is then 9600 baud, no parity, 8 data bits, and 1 stop bit. Note that if you pick the decoded "barcode" version of this scanner/cable (the cable has a DB9 connector with squeeze locking ring and outputs Wand Emulation signals), that you will need to configure it as "SYMBOL WAND".

Symbol LS-1004-I100-7700Z

When using this laser scanner with any terminal, set the scanner in Synapse Host mode. When using this laser scanner with the LANpoint/TIMEpoint/FACTORYpoint products (but not the PROs or the LANpointCE), also set the scanner Variable Leading Margin parameter to 140 milliseconds instead of the factory default 80 milliseconds.

Symbol LS1902T-I000

When using this laser scanner with the 25-32465-20 serial cable, be aware that the laser's COM port communications parameters are shipped from Symbol with the factory default communications parameters set to 9600,n,8,1. Be sure to configure the LANpoint terminal to match the communication parameters of the laser scanner or vice-versa. Once the communications parameters are set, you must scan the configuration barcode labeled "Standard RS232-C" in the LS1900 Series Quick Reference Guide for the scanner to communicate correctly.

Symbol LS1902T-I000

When using this laser scanner with the 25-51618-21 cable with (discontinued) LANpoint/TIMEpoint/FACTORYpoint terminals (but not the LANpoint PRO, FACTORYpoint PRO, or the LANpoint CE), set the scanner Variable Leading Margin parameter to 140 milliseconds instead of the factory default 80 milliseconds. You can find the barcode code commands for programming the Variable Leading Margin in the LS1900 Series Product Reference Guide ...72-50930-02...Revision A...November 2002.

Symbol LS-3603-I200A(or I200E)

When using this laser scanner with any of our terminals, the scanner needs to be changed from the factory default. For all terminals, set the scanner in wand emulation mode. For LANpoint/FACTORYpoint/TIMEpoint (but NOT the PROs or the LANpointCE), set the scanner Variable Leading Margin parameter to 90 milliseconds instead of the factory default 80 milliseconds, or change Wand Emulator Bar Output to BAR LOW instead of the factory default BAR HIGH (either parameter change will work).

Symbol LS-4004-I000-7700Z

When using this laser scanner with the LANpoint/TIMEpoint/FACTORYpoint products (but not the PROs or the LANpointCE), set the scanner Variable Leading Margin parameter to 140 milliseconds instead of the factory default 80 milliseconds.

Symbol LT-1810-I100A(or I100E)

When using this laser scanner with the LANpoint/TIMEpoint/FACTORYpoint products (but not the PROs or the LANpointCE), the scanner Variable Leading Margin parameter needs to be changed 90 milliseconds instead of the factory default 80 milliseconds.

PSC Powerscan 0611001-010004-100

When using this laser scanner with the any LANpoint terminal, change the Idle State to high from the factory default of low.

Datalogic Heron-G D130 PN:902401000

When using this CCD scanner with USB on LANpoint XL use the CAB-412 cable (without ext. power) and the default settings of the scanner

Datalogic Firescan D131 PN:902351122

When using this laser scanner with USB on LANpoint XL use the CAB-412 cable (without ext. power) and the default settings of the scanner